Equipment installed on this project
Elvira, Marbella: R-22 Pool Heater Decommissioned — Johnson JSP23VN Inverter Installed
Case Study: End-of-Life Heat Siphon Europe SX 3.25 HP Replaced with Modern Inverter Pool Heat Pump
Project Photos




The Challenge: A Condemned Unit Running on Banned Refrigerant
The Elvira villa had a Heat Siphon Europe SX 3.25 HP pool heat pump that had been in service since the early 2000s. The situation had become critical for several reasons:
- The unit used R-22 refrigerant — banned for servicing in the EU since 2015 under F-Gas Regulation 517/2014
- Refrigerant top-ups were no longer legally possible; any leak meant the unit was unserviceable
- Fixed-speed compressor technology offered COP of only ~5.3 under optimal conditions — far below modern standards
- Ageing components and degraded performance meant the pool temperature was inconsistent and unreliable
- Swimming season had progressively shortened as efficiency declined over two decades of service
R-22 (also known as Freon or HCFC-22) is a hydrochlorofluorocarbon refrigerant that was phased out across Europe due to its severe environmental impact:
- R-22 has a Global Warming Potential (GWP) of 1,810 — nearly three times higher than R-32
- EU Regulation 517/2014 banned the use of reclaimed R-22 for servicing equipment from 1 January 2015
- Any HVAC technician servicing R-22 equipment or topping up refrigerant risks significant fines
- Insurance may be invalidated if equipment uses condemned refrigerants
- The Heat Siphon Europe SX 3.25 HP was therefore not just inefficient — it was legally unserviceable
Agua Therm recovered the remaining R-22 refrigerant using certified F-Gas recovery equipment in compliance with EU Regulation 517/2014 before decommissioning the unit.
Our Recommendation: Johnson JSP23VN Inverter Pool Heat Pump
After assessing the pool volume and the property's requirements, our specialists recommended the Johnson JSP23VN — the mid-range inverter model from Johnson's 2025 pool heat pump lineup. Here's why it was the right choice:
Full Inverter Variable-Speed Compressor
Output modulates continuously between minimum and maximum capacity, consuming only the energy needed — no wasted on/off cycling at full power like the old fixed-speed unit
COP Up to 14.5 — Nearly 3× More Efficient
Tested COP of 6.36 to 14.5 under standard conditions (26°C air / 28°C water) versus the old unit's ~5.3 COP at best — typically 65–70% lower running costs
Ultra-Quiet: 25–34 dB(A) at 10 Metres
One of the quietest pool heat pumps on the Spanish market. At 10 metres distance, 25–34 dB(A) is comparable to a library — far quieter than the old fixed-speed R-22 compressor
R32 Eco Refrigerant
GWP of 675 — 63% lower than the R-22 it replaces. Future-proof under current and anticipated EU F-Gas legislation
A Energy Rating — TÜV Rheinland Certified
Independently verified A-class energy performance by TÜV Rheinland. The highest efficiency class available for pool heat pumps in Europe
Installation Results
Verified Efficiency Gains: Old vs New
The performance difference between the condemned Heat Siphon unit and the new Johnson inverter is substantial. These comparisons are based on verified technical data:
COP improved from ~5.3 to up to 14.5
The old Heat Siphon SX 3.25 HP achieved 19.6 kW from 3,700 W input — a COP of approximately 5.3 at 27°C air / 22°C water. The Johnson JSP23VN achieves COP 6.36–14.5 at 26°C / 28°C, with higher COPs at the part-load conditions typical of Costa del Sol mornings and evenings
Heat Siphon Europe data plate / Johnson official datasheet65–70% estimated reduction in pool heating running costs
Based on comparative COP data and typical inverter part-load advantage. For a pool operating 8 months per year in Marbella, this can represent several hundred euros annually
European Heat Pump Association (EHPA)R-22 GWP 1,810 → R32 GWP 675: a 63% reduction
The refrigerant change alone represents a major environmental improvement. R-22 is one of the most harmful HVAC refrigerants still found in legacy equipment
EU Regulation 517/2014 (F-Gas Regulation)Noise reduced to 25–34 dB(A) at 10m — whisper-quiet operation
Old fixed-speed R-22 pool heat pumps of that era typically operated at 55–65 dB(A) at 1 metre. The JSP23VN's full inverter at low load achieves 25 dB(A) at 10m — inaudible at typical garden distances
Johnson JSP23VN official specificationsPool heat pumps are recognised under EU Directive 2018/2001 (Renewable Energy Directive) as renewable energy technology when achieving Seasonal Performance Factor (SPF) above 2.5. The Johnson JSP23VN significantly exceeds this threshold.

"The Heat Siphon SX 3.25 HP is an old workhorse — well-built for its era, but using R-22 means it's been on borrowed time since 2015. Once you've confirmed a unit runs R-22, there's really no decision to make: it cannot be legally serviced, so it needs to come out. What I tell clients is that this is actually great news for them, because the inverter pool heat pumps we install today are in a completely different league. The Johnson JSP23VN at Elvira is going to give them COP values of 8, 10, even 12 or 13 during the mild spring and autumn days in Marbella. That's when you really want to swim — April, May, October — and that's exactly when an inverter heat pump is at its most efficient. The old fixed-speed unit would have struggled to justify its running costs at those temperatures. The new one barely draws a couple of kilowatts."
Rob Greeves
HVAC Director, Agua Therm

"Decommissioning an R-22 unit has to be done properly. We use certified F-Gas recovery equipment to extract the refrigerant before disconnecting — you cannot simply vent it, and any contractor who does is in serious breach of EU regulations. Once the old Heat Siphon was safely decommissioned, we inspected the existing pool circuit. The good news here was that the old unit ran on a single-phase 220V supply with its own dedicated circuit — the wiring was sound and appropriately rated for a unit of similar draw. The Johnson JSP23VN runs on 230V single phase with a maximum draw of 14.3A — comfortably within what was already there, with some headroom. We fitted a new MCB and verified the earthing connections, but the client saved the cost of a full new cable run. This is not always the case — always have the circuit inspected before assuming it's adequate."
Craig Whitham
Electrical Director, Agua Therm
Professional Installation Process
Our certified technicians completed the full replacement with full compliance and meticulous attention to detail:
Why Johnson Pool Heat Pumps for the Costa del Sol?
Johnson (by SAS Electric Smart Technology, Alicante) has built a strong reputation in the Spanish pool heating market specifically:
- Manufactured and distributed from Spain — short supply chain, local technical support
- Full inverter technology across the range, not just the premium models
- A-rated energy efficiency independently certified by TÜV Rheinland
- R32 refrigerant standard across all models — compliant with current and anticipated F-Gas legislation
- IPX4 weatherproofing — rated for year-round outdoor exposure on the Costa del Sol
- Competitive pricing compared to equivalent Zodiac, Hayward, or Pentair units
Location: Elvira, Marbella, Costa del Sol
Agua Therm provides professional pool heat pump installation and replacement throughout the Costa del Sol, including Marbella, Estepona, Benahavís, Fuengirola, and Mijas.
Frequently Asked Questions
Related Case Studies
Also see
About the Author

Ben Hayden
English-Speaking Electrician & Independent Energy Advisor
Ben Hayden is an English speaking electrician and independent energy advisor based in Marbella, Spain, with over 15 years of electrical experience across Europe. He provides independent energy and electrical checks for overseas property owners and managers across the Costa del Sol — helping clients cut electricity bills, navigate Spanish regulations, and make confident decisions on solar PV, heat pump, EV charger and battery storage projects.
Ben advises in plain English on projects where the paperwork is in Spanish and the stakes are high. His writing has appeared in ExpatArrivals, The Olive Press, Euro Weekly News, BuildingTalk and pv magazine.