Skip to main content

    Equipment installed on this project

    Johnson Controls logo
    R-22 Decommissioned
    Pool Heating
    A Rated

    Elvira, Marbella: R-22 Pool Heater Decommissioned — Johnson JSP23VN Inverter Installed

    Case Study: End-of-Life Heat Siphon Europe SX 3.25 HP Replaced with Modern Inverter Pool Heat Pump

    Elvira, Marbella
    March 2026
    COP up to 14.5
    25–34 dB(A)
    Prices shown are for this specific completed project. Every installation is different — your costs will depend on your property, access, and system requirements and are confirmed after a free site survey. Contact us for a free quote.

    Project Photos

    Heat Siphon Europe SX 3.25 HP — condemned R-22 pool heat pump awaiting removal, Elvira Marbella
    Heat Siphon Europe SX 3.25 HP — condemned R-22 unit before removal
    Heat Siphon Europe SX 3.25 HP data plate showing R-22 refrigerant and specifications
    Data plate: R-22 refrigerant, 19.6 kW, manufactured ~2003
    Johnson JSP23VN Inverter installed next to pool plant room, Elvira Marbella
    Johnson JSP23VN installed alongside pool filter and pump
    Johnson JSP23VN data plate showing COP 14.5, R32 refrigerant and A energy rating
    JSP23VN data plate: R32, COP up to 14.5, A-rated TÜV Rheinland
    Project Overview
    Location: Elvira, Marbella
    Property: Private Villa with Pool
    Old System: Heat Siphon Europe SX 3.25 HP (R-22 — Condemned)
    New System: Johnson JSP23VN Inverter Pool Heat Pump
    Refrigerant: R32 (GWP 675) — replaces banned R-22
    Date: March 2026

    The Challenge: A Condemned Unit Running on Banned Refrigerant

    The Elvira villa had a Heat Siphon Europe SX 3.25 HP pool heat pump that had been in service since the early 2000s. The situation had become critical for several reasons:

    • The unit used R-22 refrigerant — banned for servicing in the EU since 2015 under F-Gas Regulation 517/2014
    • Refrigerant top-ups were no longer legally possible; any leak meant the unit was unserviceable
    • Fixed-speed compressor technology offered COP of only ~5.3 under optimal conditions — far below modern standards
    • Ageing components and degraded performance meant the pool temperature was inconsistent and unreliable
    • Swimming season had progressively shortened as efficiency declined over two decades of service
    Why R-22 Equipment Must Be Replaced

    R-22 (also known as Freon or HCFC-22) is a hydrochlorofluorocarbon refrigerant that was phased out across Europe due to its severe environmental impact:

    • R-22 has a Global Warming Potential (GWP) of 1,810 — nearly three times higher than R-32
    • EU Regulation 517/2014 banned the use of reclaimed R-22 for servicing equipment from 1 January 2015
    • Any HVAC technician servicing R-22 equipment or topping up refrigerant risks significant fines
    • Insurance may be invalidated if equipment uses condemned refrigerants
    • The Heat Siphon Europe SX 3.25 HP was therefore not just inefficient — it was legally unserviceable

    Agua Therm recovered the remaining R-22 refrigerant using certified F-Gas recovery equipment in compliance with EU Regulation 517/2014 before decommissioning the unit.

    Our Recommendation: Johnson JSP23VN Inverter Pool Heat Pump

    After assessing the pool volume and the property's requirements, our specialists recommended the Johnson JSP23VN — the mid-range inverter model from Johnson's 2025 pool heat pump lineup. Here's why it was the right choice:

    Full Inverter Variable-Speed Compressor

    Output modulates continuously between minimum and maximum capacity, consuming only the energy needed — no wasted on/off cycling at full power like the old fixed-speed unit

    COP Up to 14.5 — Nearly 3× More Efficient

    Tested COP of 6.36 to 14.5 under standard conditions (26°C air / 28°C water) versus the old unit's ~5.3 COP at best — typically 65–70% lower running costs

    Ultra-Quiet: 25–34 dB(A) at 10 Metres

    One of the quietest pool heat pumps on the Spanish market. At 10 metres distance, 25–34 dB(A) is comparable to a library — far quieter than the old fixed-speed R-22 compressor

    R32 Eco Refrigerant

    GWP of 675 — 63% lower than the R-22 it replaces. Future-proof under current and anticipated EU F-Gas legislation

    A Energy Rating — TÜV Rheinland Certified

    Independently verified A-class energy performance by TÜV Rheinland. The highest efficiency class available for pool heat pumps in Europe

    Installation Results

    Up to 14.5
    New COP
    Full Inverter
    Technology
    R32 Eco
    Refrigerant
    25–34 dB(A)
    Noise at 10m

    Verified Efficiency Gains: Old vs New

    The performance difference between the condemned Heat Siphon unit and the new Johnson inverter is substantial. These comparisons are based on verified technical data:

    COP improved from ~5.3 to up to 14.5

    The old Heat Siphon SX 3.25 HP achieved 19.6 kW from 3,700 W input — a COP of approximately 5.3 at 27°C air / 22°C water. The Johnson JSP23VN achieves COP 6.36–14.5 at 26°C / 28°C, with higher COPs at the part-load conditions typical of Costa del Sol mornings and evenings

    Heat Siphon Europe data plate / Johnson official datasheet

    65–70% estimated reduction in pool heating running costs

    Based on comparative COP data and typical inverter part-load advantage. For a pool operating 8 months per year in Marbella, this can represent several hundred euros annually

    European Heat Pump Association (EHPA)

    R-22 GWP 1,810 → R32 GWP 675: a 63% reduction

    The refrigerant change alone represents a major environmental improvement. R-22 is one of the most harmful HVAC refrigerants still found in legacy equipment

    EU Regulation 517/2014 (F-Gas Regulation)

    Noise reduced to 25–34 dB(A) at 10m — whisper-quiet operation

    Old fixed-speed R-22 pool heat pumps of that era typically operated at 55–65 dB(A) at 1 metre. The JSP23VN's full inverter at low load achieves 25 dB(A) at 10m — inaudible at typical garden distances

    Johnson JSP23VN official specifications

    Pool heat pumps are recognised under EU Directive 2018/2001 (Renewable Energy Directive) as renewable energy technology when achieving Seasonal Performance Factor (SPF) above 2.5. The Johnson JSP23VN significantly exceeds this threshold.

    Expert Insight: When Replacement Is the Only Option
    Rob Greeves
    "The Heat Siphon SX 3.25 HP is an old workhorse — well-built for its era, but using R-22 means it's been on borrowed time since 2015. Once you've confirmed a unit runs R-22, there's really no decision to make: it cannot be legally serviced, so it needs to come out. What I tell clients is that this is actually great news for them, because the inverter pool heat pumps we install today are in a completely different league. The Johnson JSP23VN at Elvira is going to give them COP values of 8, 10, even 12 or 13 during the mild spring and autumn days in Marbella. That's when you really want to swim — April, May, October — and that's exactly when an inverter heat pump is at its most efficient. The old fixed-speed unit would have struggled to justify its running costs at those temperatures. The new one barely draws a couple of kilowatts."

    Rob Greeves

    HVAC Director, Agua Therm

    Decommissioning Old Equipment: The Electrical and Refrigerant Side
    Craig Whitham
    "Decommissioning an R-22 unit has to be done properly. We use certified F-Gas recovery equipment to extract the refrigerant before disconnecting — you cannot simply vent it, and any contractor who does is in serious breach of EU regulations. Once the old Heat Siphon was safely decommissioned, we inspected the existing pool circuit. The good news here was that the old unit ran on a single-phase 220V supply with its own dedicated circuit — the wiring was sound and appropriately rated for a unit of similar draw. The Johnson JSP23VN runs on 230V single phase with a maximum draw of 14.3A — comfortably within what was already there, with some headroom. We fitted a new MCB and verified the earthing connections, but the client saved the cost of a full new cable run. This is not always the case — always have the circuit inspected before assuming it's adequate."

    Craig Whitham

    Electrical Director, Agua Therm

    Professional Installation Process

    Our certified technicians completed the full replacement with full compliance and meticulous attention to detail:

    Safe R-22 refrigerant recovery using EU-certified F-Gas equipment prior to decommissioning
    Full disconnection and removal of the Heat Siphon Europe SX 3.25 HP unit
    Site survey to confirm Johnson JSP23VN positioning for optimal airflow and access
    Inspection and verification of existing electrical circuit — MCB replaced, earthing confirmed
    Installation of Johnson JSP23VN on level anti-vibration feet alongside existing pool plant room
    Hydraulic connections to existing pool circulation pipework with correct flow/return orientation
    Commissioning: full heating cycle test, flow rate verification, and operating temperature check
    Responsible disposal of old unit in compliance with WEEE Directive

    Why Johnson Pool Heat Pumps for the Costa del Sol?

    Johnson (by SAS Electric Smart Technology, Alicante) has built a strong reputation in the Spanish pool heating market specifically:

    • Manufactured and distributed from Spain — short supply chain, local technical support
    • Full inverter technology across the range, not just the premium models
    • A-rated energy efficiency independently certified by TÜV Rheinland
    • R32 refrigerant standard across all models — compliant with current and anticipated F-Gas legislation
    • IPX4 weatherproofing — rated for year-round outdoor exposure on the Costa del Sol
    • Competitive pricing compared to equivalent Zodiac, Hayward, or Pentair units
    Johnson JSP23VN — Full Technical Specifications
    Heating Capacity4.8–21.6 kW (26°C air / 28°C water)
    Power Input (Heating)0.33–3.42 kW
    COP6.36–14.5 (standard conditions)
    Cooling Capacity4.3–11.5 kW
    EER4.38–7.48
    RefrigerantR32 — 1.8 kg charge, GWP 675
    Power Supply230V / 50Hz / Single Phase
    Maximum Current14.3 A
    Water Flow Rate7–9 m³/h
    Operating Temp Range-15°C to +43°C
    Noise Level (10m)25–34 dB(A)
    IP RatingIPX4
    Dimensions (Net)1,076 × 426 × 720 mm
    Net Weight67 kg
    Energy RatingA (most efficient) — TÜV Rheinland
    Johnson official datasheet / Heat Siphon Europe SX 3.25 HP data plate
    Heat Siphon Europe SX 3.25 HP — Decommissioned Unit
    ModelHeat Siphon Europe SX 3.25 HP
    Heating Capacity19.6 kW (27°C air / 22°C water, RF 80%)
    Nominal Power3,700 W
    Estimated COP~5.3 (at rated conditions — degraded in practice)
    RefrigerantR-22 — 2.25 kg charge (GWP 1,810 — banned)
    Power Supply220V / 1Ph / 50Hz
    CompressorFixed-speed, 20 RLA / 115 LRA
    StatusDecommissioned — R-22 unserviceable under EU law

    Location: Elvira, Marbella, Costa del Sol

    Agua Therm provides professional pool heat pump installation and replacement throughout the Costa del Sol, including Marbella, Estepona, Benahavís, Fuengirola, and Mijas.

    Frequently Asked Questions

    Have an Old R-22 Pool Heat Pump in Marbella?

    If your pool heater uses R-22 refrigerant, it cannot be legally serviced. Contact Agua Therm for a free assessment and quote to upgrade to a modern inverter unit. We handle safe decommissioning, supply, and full installation.

    Related Case Studies

    Also see

    About the Author

    Ben Hayden

    Ben Hayden

    English-Speaking Electrician & Independent Energy Advisor

    Ben Hayden is an English speaking electrician and independent energy advisor based in Marbella, Spain, with over 15 years of electrical experience across Europe. He provides independent energy and electrical checks for overseas property owners and managers across the Costa del Sol — helping clients cut electricity bills, navigate Spanish regulations, and make confident decisions on solar PV, heat pump, EV charger and battery storage projects.

    Ben advises in plain English on projects where the paperwork is in Spanish and the stakes are high. His writing has appeared in ExpatArrivals, The Olive Press, Euro Weekly News, BuildingTalk and pv magazine.

    Important notice regarding subsidies: Do not base a purchase on an unconfirmed grant. An application is not an award or receipt of payment. Check the current official call, eligibility and each deadline with the administering authority or an independent specialist before making a financial decision. Agua Therm installs; we do not manage subsidy applications.

    WhatsApp